Description
Function of the Static Monofan Air Steam
Filled retort baskets are inserted into the STERISTEAM. The door is closed then locked automatically through a hydraulic cylinder. It is mechanically blocked throughout the entire cycle.
Pre-heating of the enclosure is carried out by direct-steam-injection. Pre-heating temperature can be adjusted (e.g. 100°C – 0.2 bar) and air vent valve open. Adjustable period (e.g. 5 minutes).
Heating phase can be started. Heat is produced in the enclosure by direct-steam-injection. Dissemination will be made between each basket. Graduated acting steam valve opening is monitored by MPI until the set temperature is reached, for instance 121°C. In this heating-up phase, the fan is on. The operation of the fan is continually monitored. Condensates are stored in the lower part of the enclosure.
Once the scheduled duration of the bearing comes to an end : pre-cooling starts. It is performed by injecting cold water in the vessel via two lateral spray headers. This water accumulates at the lower section in addition to the condensates previously accumulated. The water level is controlled by a radar level and managed by MPI.
Once the set temperature is reached, final cooling is carried out by cascading recycled water on the load.
How does the cascading system operates ? Recycled water is made with steam condensates previously accumulated in previous phases as well as water make up. The mixture is pumped at the sterilizer lower section through the secondary circuit of an external heat exchanger (plates and gaskets), and returned on water distributor laid out on top of the load to cool.
Technical specifications :
Standard sizes :
- 1300 mm, corresponding to maximum size of manually operable basket (476 cans 4/4) and a capacity from 4 to 6 paniers.
- 1450 mm
- 1600 mm
- 1800 mm,
- 2000 mm,
*We also have the capacity to adapt to your needs. Do not hesitate to contact us to discuss your specific requirements.
The cooling capacity :
Steristream has a powerful pump coupled with high flows of cascading water. It provides shorter cycles more homogeneous compared to other Air Steam retorts on the market. All products within the autoclave are treated the same wherever they are located. Reducing time cycles also provides better operating performance.
Radar level :
Enables to accurately control the volume of water at the cooling phase.
Benefits :
- Safety door
- A very effective cooling capacity
- Time-tested design in all diameter ranges
Types of packaging or products :
- Prepared Pet food
- Small pouches
Reviews